From Philip Nippins, Camden, NJ

 

 

 

140

GROUND MAINTENANCE                                                     1.00 DU                  ________                                            ________

Ground maintenance: Cut, trim and maintain all grass to 3/4" in height between April 1st and October 31st. Remove snow, maintaining all walks and passage areas in a clean and safe condition between November 1st and March 31st.

 

1.00

MO

$80

3580

FRONT PORCH ASSEMBLY WITH ROOF                             1.00 SF                  ________                                            ________

Excavate 36" below grade, form and pour three 12" diameter 2400 PSI piers with 2, #5 rebar, tied lengthwise, 2" off center, vibrate concrete. Cast galvanized anchor plate at finish surface. After 2 days remove forms. Install 2” x 8” preservative treated pine joists 16" O.C., crown up from 2” x 8” ledge to double 2” x 8” header to create a 8’ x 6’ deck. Nail 1x3 yellow pine T&G decking to joist with concealed galvanized nails. Install three 5” x 5” turned wood posts on a 2”x 8" x 8" PT pine plinth block. Frame a hip roof with a triple 2” x 10” beam on top of posts, 2” x 6” ceiling joists and 2” x 8” rafters 16" O.C. Nail 1/2" CDX plywood sheathing 8" O.C. Install GAF Ice and water dam 36" at eaves, 15 lb. felt and GAF Timberline shingles with a 25 year warranty, 6 nails per shingle, color by owner. Install .019 aluminum step and counterflashing. 5" aluminum "K" gutter and leaders, connected to city sewer. Create a 36" high railing around porch using PT top and bottom rails and 2” x 2” baluster 4" O.C. Frame skirt using PT 1” x 4” 24" O.C. and 1/4" x 2" pine lattice. Construct 36" wide stair unit with three 2” x12” PT stringers, 5/4" x 12" PT treads and 1" X PT risers on a solid 36" x 12" x 6" wide concrete footer.

 

1.00

SF

$23

6958

BATHTUB/SHOWER--5' FIBERGLASS--COMPLETE             1.00 EA                  ________                                            ________

Install a 5', 4 piece, Sterling 71020110 Series 7102 V-60-HG

60" Tub/Shower - unit complete with lever operated pop up

drain and overflow, PVC waste, single lever shower diverter,

shower rod and Delta Faucet "Monitor" Model 1343  tub/shower faucet - and a water  saver showerhead with a maximum 2.0 GPM flow rate.   Set tub in mortar base, insulate exterior walls R-13 and draft stop using housewrap.

 

1.00

EA

$700


 

8703

CORE WALL/PARTY WALL/FIREWALL                              1.00 SF                  ________                                           ________

Construct an H-Stud wall, a non-load bearing 2 hour fire and separation assembly of gypsum panels and steel studs. Screw a metal U channel to top of masonry foundation and at firestopping.  Screw H-Studs 24" O.C. to bottom track. Hang two layers of 1" Fire-Shield Gypsum shaft liner.  Maintain a 1" airspace between assembly and adjacent solid construction. Attach H-Studs to both sides of the adjacent framing members with 1220 degree F. melting point angle clips. Seal all joints and roof/wall firestopping with fire retardant caulk to create a smoketight joint. The maximum height of the firewall is 44'. No penetrations allowed through firewall. Firestop all floor, ceiling openings and all terminations through roof or exterior walls with 1" Type X shaft liner. Seal all visible joints with fire retardant caulk to create a smoketight joint.

 

1.00

SF

$4

 

From Joseph Mannion, Westmont, NJ

 

 

 

7430

INSPECT AND REPORT ELECTRIC SYSTEM                        1.00 AL                  ________                                           ________

Licensed electrician shall inspect all electrical devices, wiring and panels to identify antiquated components, shorts, malfunctioning equipment and noncompliance with 2006 N.E.C. Submit an itemized and priced scope of work of interior and exterior electrical repairs required to bring the building into full compliance with the 2006 National Electrical Code.

 

1.00

AL

$0

 

From Ricardo Rosario, Jersey City, NJ

 

 

 

5425

CERAMIC FLOOR TILE- 12" x 12"                                       1.00 SF                  ________                                           ________

Install 1/2" reinforced cement board, screwed 6” o.c. to subfloor. Maintain a ventilated environment, above 50 degrees F during installation. Using Type I thin set adhesive, lay owner's choice of 12" x 12" x 1/4” of $3/SF ceramic floor tile. After at least 24 hours drying time, apply latex-Portland grout. Clean floor, seal with siliconized grout sealant and apply mildew resistant white silicone caulk to all edge seams and pipe penetration. Install a 3-1/2” x 1/2” marble threshold with honed finish by full width of frame opening beveled both sides.

 

1.00

SF

$6

7816

FIXTURE--HEAT, LIGHT, VENT                                            1.00 EA                  ________                                           ________

Install a ceiling mounted fixture containing a 1200 watt, forced

air heater, a single bulb light fixture, and an exterior ducted

vent fan with damper capable of 100 cfm, on an independent 20 amp circuit, using #14 copper Romex.  Switch fan & light using a single switch with a time delay for the fan such as the EFI Fan/Light Time Delay Switch part # 5100.502. Fish all wire and patch all tear out.

 

1.00

EA

$275

3751

COUNTER TOP- GRANITE                                                   1.00 AL                  ________                                           ________

Field measure and create template of counter top. Screw fully supported 1/2" plywood deck to base cabinet. Set a granite slab counter top w/ 3/8" round edges and 4" back splash w/ cutout for a 31-1/2'' x 18'" undermount sink. Ensure there are no gaps between counter top and any walls. At the junction of counter top or back splash and wall, apply a 1/4" bead of clear silicone caulk with at least a 10 year warranty. Owner's choice of stone color and pattern.

 

1.00

SF

$55

 

 
   