The specs below were submitted by Certfied Rehab Specialists and NRSF members Philip Nippins, Camden, NJ - Joseph Mannion, Westmont, NJ
- Ricardo Rosario, Jersey City, NJ
Spec #
Spec
Quantity
Unit
Cost
From
Philip Nippins, Camden, NJ
140
GROUND
MAINTENANCE1.00DU________________
Ground
maintenance: Cut, trim and maintain all grass to 3/4" in height between
April 1st and October 31st. Remove snow, maintaining all walks and passage
areas in a clean and safe condition between November 1st and March 31st.
1.00
MO
$80
3580
FRONT
PORCH ASSEMBLY WITH ROOF1.00SF________________
Excavate
36" below grade, form and pour three 12" diameter 2400 PSI piers
with 2, #5 rebar, tied lengthwise, 2" off center, vibrate concrete. Cast
galvanized anchor plate at finish surface. After 2 days remove forms. Install
2” x 8” preservative treated pine joists 16" O.C., crown up from 2” x 8”
ledge to double 2” x 8” header to create a 8’ x 6’
deck. Nail 1x3 yellow pine T&G decking to joist with concealed galvanized
nails. Install three 5” x 5” turned wood posts on a 2”x 8" x 8" PT
pine plinth block. Frame a hip roof with a triple 2” x 10” beam on top of
posts, 2” x 6” ceiling joists and 2” x 8” rafters 16" O.C. Nail
1/2" CDX plywood sheathing 8" O.C. Install GAF Ice and water dam
36" at eaves, 15 lb. felt and GAF Timberline shingles with a 25 year
warranty, 6 nails per shingle, color by owner. Install .019 aluminum step and counterflashing. 5" aluminum "K"
gutter and leaders, connected to city sewer. Create a 36" high railing
around porch using PT top and bottom rails and 2” x 2” baluster 4" O.C.
Frame skirt using PT 1” x 4” 24" O.C. and 1/4" x 2" pine
lattice. Construct 36" wide stair unit with three 2” x12” PT stringers,
5/4" x 12" PT treads and 1" X PT risers on a solid 36" x
12" x 6" wide concrete footer.
Install
a 5', 4 piece, Sterling 71020110 Series 7102 V-60-HG
60"
Tub/Shower - unit complete with lever operated pop up
drain and
overflow, PVC waste, single lever shower diverter,
shower rod
and Delta Faucet "Monitor" Model 1343tub/shower faucet - and a watersaver showerhead with a maximum 2.0 GPM flow rate.Set tub in mortar base,
insulate exterior walls R-13 and draft stop using housewrap.
Construct
an H-Stud wall, a non-load bearing 2 hour fire and
separation assembly of gypsum panels and steel studs. Screw a metal U channel
to top of masonry foundation and at firestopping.Screw H-Studs 24" O.C. to bottom
track. Hang two layers of 1" Fire-Shield Gypsum shaft liner.Maintain a 1"
airspace between assembly and adjacent solid construction. Attach H-Studs to
both sides of the adjacent framing members with 1220 degree F. melting point angle clips. Seal all joints and roof/wall firestopping with fire retardant caulk to create a smoketight joint. The maximum height of the firewall is
44'. No penetrations allowed through firewall. Firestop all floor, ceiling openings and all terminations through roof or exterior
walls with 1" Type X shaft liner. Seal all visible joints with fire
retardant caulk to create a smoketight joint.
1.00
SF
$4
From
Joseph Mannion, Westmont, NJ
7430
INSPECT
AND REPORT ELECTRIC SYSTEM1.00AL________________
Licensed
electrician shall inspect all electrical devices, wiring and panels to
identify antiquated components, shorts, malfunctioning equipment and
noncompliance with 2006 N.E.C. Submit an itemized and priced scope of work of
interior and exterior electrical repairs required to bring the building into
full compliance with the 2006 National Electrical Code.
1.00
AL
$0
From Ricardo Rosario, Jersey City, NJ
5425
CERAMIC FLOOR TILE- 12" x 12"1.00SF________________
Install 1/2" reinforced cement board,
screwed 6” o.c. to subfloor. Maintain a ventilated environment, above 50
degrees F during installation. Using Type I thin set adhesive, lay owner's
choice of 12" x 12" x 1/4” of $3/SF ceramic floor tile. After at
least 24 hours drying time, apply latex-Portland grout. Clean floor, seal
with siliconized grout sealant and apply mildew
resistant white silicone caulk to all edge seams and pipe penetration.
Install a 3-1/2” x 1/2” marble threshold with honed finish by full width of
frame opening beveled both sides.
1.00
SF
$6
7816
FIXTURE--HEAT, LIGHT, VENT1.00EA________________
Install a ceiling mounted fixture containing a
1200 watt, forced
air heater, a single bulb light fixture, and an
exterior ducted
vent fan with damper capable of 100 cfm, on an independent 20 amp circuit, using #14 copper Romex.Switch fan & light using a single switch with a time delay for the
fan such as the EFI Fan/Light Time Delay Switch part # 5100.502. Fish all
wire and patch all tear out.
1.00
EA
$275
3751
COUNTER TOP- GRANITE1.00AL________________
Field measure and create template of counter top.
Screw fully supported 1/2" plywood deck to base cabinet. Set a granite
slab counter top w/ 3/8" round edges and 4" back splash w/ cutout
for a 31-1/2'' x 18'" undermount sink. Ensure
there are no gaps between counter top and any walls. At the junction of
counter top or back splash and wall, apply a 1/4" bead of clear silicone
caulk with at least a 10 year warranty. Owner's
choice of stone color and pattern.